Contact Us

 

Please leave us a message,

we'll get back to you as soon as possible.

 

Best Regards,

         

123 Street Avenue, City Town, 99999

(123) 555-6789

email@address.com

 

You can set your address, phone number, email and site description in the settings tab.
Link to read me page with more information.

produit

40Ah Batterie Lithium-ion (SP-LFP40AHA)

sig energy

DESCRIPTION
Marque SINOPOLY
Référence SP-LFP-40AHA
Poids1.5 ± 0.1 kg
Capacité nominale40Ah
Tension nominale3.2V
Résistance interne (1 kHz AC)≤ 0.8mΩ
Cycle de vie (0.3C 80% DOD)≥2000
Taux d’autodécharge (25°C, 1 mois)≤ 5%
OPERATING CONDITIONS
Courant nominal de charge (CC&CV)13A
Courant de charge maximum (1C)80A
Tension de charge limitée3.65V
Courant de fin de charge (0.02C)0.8A
Courant nominal de décharge13A
Courant maximum de décharge120A
Tension de coupure de décharge2.5V
Température de chargement0℃ - 45℃
Température de déchargement-20℃ - 55℃
Température de stockage-10℃ - 45℃
Humidité de stockage25% - 85%
DIMENSION
Hauteur186±1mm
Largeur116±1mm
Épaisseur46±0.5mm
 

60Ah Batterie Lithium-ion (SP-LFP60AHA(A))

sig energy

DESCRIPTION
Marque SINOPOLY
Référence SP-LFP-60AHA (A)
Poids2 ± 0.1 kg
Capacité nominale60Ah
Tension nominale3.2V
Résistance interne (1 kHz AC)≤ 0.8mΩ
Cycle de vie (0.3C 80% DOD)≥2000
Taux d’autodécharge (25°C, 1 mois)≤ 5%
OPERATING CONDITIONS
Courant nominal de charge (CC&CV)20A
Courant de charge maximum (1C)120A
Tension de charge limitée3.65V
Courant de fin de charge (0.02C)1.2A
Courant nominal de décharge20A
Courant maximum de décharge180A
Tension de coupure de décharge2.5V
Température de chargement0℃ - 45℃
Température de déchargement-20℃ - 55℃
Température de stockage-10℃ - 45℃
Humidité de stockage25% - 85%
DIMENSION
Hauteur184±1mm
Largeur116±1mm
Épaisseur61±0.5mm
 

300Ah Batterie Lithium-ion (SP-LFP-300AHA)

sig energy

DESCRIPTION
Marque SINOPOLY
Référence SP-LFP-300AHA
Poids9.5 ± 0.3 kg
Capacité nominale300Ah
Tension nominale3.2V
Résistance interne (1 kHz AC)≤ 0.4mΩ
Cycle de vie (0.3C 80% DOD)≥1500
Taux d’autodécharge (25°C, 1 mois)≤ 5%
OPERATING CONDITIONS
Courant nominal de charge (CC&CV)99A
Courant de charge maximum (1C)300A
Tension de charge limitée3.65V
Courant de fin de charge (0.02C)6A
Courant nominal de décharge99A
Courant maximum de décharge300A
Tension de fin de décharge2.5V
Température de chargement0℃ - 45℃
Température de déchargement-20℃ - 55℃
Température de stockage-10℃ - 45℃
Humidité de stockage25% - 85%
DIMENSION
Hauteur308±1mm
Largeur360±1mm
Épaisseur53±0.5mm
 

4ooAh Batterie Lithium-ion (SP-LFP-400AHA)

sig energy

DESCRIPTION
Marque SINOPOLY
Référence SP-LFP-400AHA
Poids14.3 ± 0.3 kg
Capacité nominale400Ah
Tension nominale3.2V
Résistance interne (1 kHz AC)≤ 0.3mΩ
Cycle de vie (0,3C 80% DOD)≥1500
Taux d’autodécharge (25°C, 1 mois)≤ 5%
OPERATING CONDITIONS
Courant nominal de charge (CC&CV)132A
Courant de charge maximum (1C)400A
Tension de charge limitée3.65V
Courant de fin de charge (0.02C)8A
Courant nominal de décharge132A
Courant maximum de décharge400A
Tension de fin de décharge2.5V
Température de chargement0℃ - 45℃
Température de déchargement-20℃ - 55℃
Température de stockage-10℃ - 45℃
Humidité de stockage25% - 85%
DIMENSION
Hauteur285±1mm
Largeur450±1.5mm
Épaisseur71±0.5mm
 

YN.BMS LEV-01

sig energy

Reference: YN.BMS LEV-01

Data acquisition /calculation /monomer battery voltage/total voltage /temperature/ current/insulation /SOC estimation) 
Communication function : CAN communication / Rs232 communication / RS485 communication
Status display function : failure alarm

Description

External dimension : 220x135x40mm
Supporting solution : with the driving and driven structure. each slave control box can control the voltage of 19 circuits
Applicable battery scope : Lead-acid battery, nickel-hydrogen battery, lithium battery and other power batteries
Operating voltage range (SOC) : 12V (9-18V), 24V (16-28V)
Operating temperature range (℃) : -40°C - 85℃
Maximum relative operating humidity : 90%

1. Basic Function

  • Data acquisition /calculation /monomer battery voltage/total voltage /temperature/ current/insulation /SOC estimation);

  • Communication function : CAN communication / Rs232 communication / RS485 communication;

  • Status display function : failure classifying alarm function, and control function (charging, discharging, heating and fan)

2. Technical Index

  • Voltage measuring accuracy: 0.5%

  • Temperature measuring range (℃) : -40°C -125℃

  • Temperature measuring accuracy (℃) : 0.5℃

  • Current measuring accuracy : 0.5%

  • SOC measuring accuracy : 5%

  • Monomer voltage cycle detection period : 1s

  • Maximum current sampling period : 1s (average current: 1s)

  • Application range of vehicle model : pure electric vehicle, hybrid power coach

  • Application example : pure automatic coach for Olympic Games, pure electric bus/floats for World Exposition

 

YN.BMS EV-02

sig energy

Reference: YN.BMS EV-02

Data acquisition /calculation (monomer battery voltage/ total voltage/ temperature/ current/ insulation/ SOC
estimation)
Communication function : CAN communication /Rs232 communication /R5485 communication
Status display function. failure classifying alarm

Description

External dimension : 240x160x42mm
Supporting solution : with the driving and driven structure, each slave control box can control the voltage of 31 circuits
Applicable battery scope : Lead-acid battery. nickel- hydrogen battery, lithium battery and other power batteries
Operating voltage range (V/DC) : 12V (9-18V), 24V (16-28V) 
Operating temperature range (°C) : -40 - 85°C
Maximum relative operating humidity : 90%

1. Basic function

  • Data acquisition /calculation (monomer battery voltage/total voltage /temperature/ current/insulation /SOCestimation);

  • Communication function : CAN communication / Rs232 communication / R5485 communication;

  • Status display function. Failure classifying alarm function, control function (charging, discharging, heatingand fan) . And single box charging function

2. Technical index

  • Voltage measuring accuracy : 0.5%

  • Temperature measuring range (°C) : 40°C - 125°C

  • Temperature measuring accuracy(°C) : 1°C

  • Current measuring accuracy : 0.5%

  • SOC measuring accuracy : 5%

  • Monomer voltage cycle detection period : 100ms

  • Maximum current sampling period : 1s (average current: 1s)

  • Application range of vehicle model : pure electric vehicle, hybrid power coach

  • Application example : sprinkling truck is an imitation vehicle. midi pure electric sedan,

  • hybrid power coach, logistic vehicle for World Exposition

 

S-SERIES BMS

sig energy

Measures 4 to 48 cell voltages in series
Measures 4 to 48 cell temperatures
12 – 200V Battery Packs
300mA Passive Cell Balancing
State of Charge, State of Health, Capacity, DC
Resistance calculations
Cell over voltage, under voltage, and high tempe

 

DESCRIPTION

 

1. PRODUCT LINE

 

2. FEATURE

  • Measures 4 to 48 cell voltages in series
  • Measures 4 to 48 cell temperatures
  • 12 – 200V Battery Packs300mA Passive Cell Balancing
  • State of Charge, State of Health, Capacity, DCResistance calculations
  • Cell over voltage, under voltage, and highTemperature hardware interlock layerProtection
  • Isolated CAN and isolated RS-232
  • Additional Digital and an alogous I/O
  • Battery Relay and pre-charge controlCurrentSensor Monitoring
  • 12 – 24V Power Supply Input Fault Management and Diagnostics
  • Data Logging
  • Ultra Low Power Dissipation
  • Automotive Grade

3. DESCRIPTIONS

The JTT S-Series Battery Management System (BMS) controllers are stand-alone Low Voltage Battery Control Systems. This all in one, single BMS controller can monitor battery packs up to 48 cells and 200V.

The S-Series controllers come in 4 different models: S1, S2, S3, and S4. The S1 can monitor 12 cells, S2 can monitor 24 cells, the S3 can monitor 36 cells, and the S4 can monitor 48 cells. Each bank of 12 cells monitors 12 cell voltages and 12 temperatures.

The S-Series balances the voltage and charge between all cells the battery pack by passive balancing. Energy is discharged from the highest charged cells in the pack, and thus maximizes the range of a battery pack and extends its life. The cell balancing is based on the amount of charge in each cell and not the cell voltage, and so balancing is active continuously during operation and not just during idle periods.

An intelligent software system runs more than 80 diagnostics at faster than 10 times a second, on both the cells and the entire battery pack. Most diagnostics are to ensure safe operation of the battery pack, and the rest are for monitoring battery performance and life.

Each S-Series controller communicates over isolated CAN bus and isolated RS-232 all battery fault conditions, cell status, and battery data to either a Display, Monitoring System, vehicle ECU or a Motor Controller depending on the end application.

In addition, the S-series controllers are equipped with 6 additional I/O signals. Four dedicated Digital I/O ports and two configurable ports that are Digital Outputs by default but can be choosed as an alogous Outputs if required. The 4Digital I/O can either control various system peripherals or receive system inputs. The an alogous Outs can be set to represent various battery parameter values.

The S-Series controller is designed to disconnect safety relays to isolate the battery in extreme operating conditions to ensure safe operation. The S-Series controller is compatible for all lithium cell chemistries such as LFP, NMC, LMO, LTO and all cell form factors such as pouch, cylindrical, or prismatic form.

4. APPLICATIONS

  • Electric, Hyb, and Plug-In Hyb Vehicles
  • Industrial Battery Packs
  • Backup and Standby Battery Systems
 

ES-DY-13

sig energy

ES-DY-13 can be applied in large, medium and small scenery storage power station, The BMS consist of; battery array unit (BAU), battery cluster unit (the BCU) and battery management unit (BMU), the triple management architecture.

1. SIZE

2. TECHNICAL PARAMETERS

NO.NamesSpecifications
1Application Scope Large, medium and small-scale energy storage power station
2External Communications equipment PCS, monitoring platform and so on
3Voltage Detection Single BMU voltage detection battery string: 16
Voltage detection range: 0 to 5 V (other voltages can be customized)
Voltage detection accuracy of ± 5mV
4Temperature DetectionSingle BMU temperature detection channels
Temperature sensing range of -40 °C to 125 °C
Temperature measurement accuracy ± 2 °C (-40 °C ~ 85 °C)
5Current DetectionCurrent ranges ± 1000A (Current sensor optional)
Current measurement accuracy of ± 1%
6BCU Module Control Signal OutputSeveral active output interface and passive output interface
7Refrigeration and Heating Output control signal
8Initiative BalanceBalance current: 2A, open 2-ways balance simultaneity
9CommunicationBAU: CAN (1-way), the RS485 (2-way), RS232 (1-way), Ethernet (2-way)
BCU: CAN (3-way), 485 (3-way)
BMU: CAN (1-way)
10Active Signal InputBCU: several ways active signal input
11Data DisplayBAU: connect touch screen through VGA
BCU: connect LCD screen through 485 BUS
BMU: connect host computer via the CAN
12SOC Estimation Error< 5%
13Failure AlarmBuzzer, LCD screen alert
14Data StorageThe BAU: ≥32GB (can be configured according to customer demand)
BCU: support 2~8G high- capacity SD data storage card
15Operation Voltage RangeBAU: 220V AC power
BCU and BMU 12V system: DC9~18V (excluding LCD screen)
BCU and BMU 24V system: DC18~32V (excluding LCD screen)
16 Operation tempreture rangeBAU: -20 ºC ~ 70 ºC
BCU: -30 ºC ~ 75 ºC
BMU: -30 ºC ~ 75 ºC
17Storage Temperature Range-40 ºC ~ 85 ºC

3. KEY FEATURES

  • High-precision voltage, current, temperature information collection and battery status estimation, comprehensively control the battery information by digital method;
  • Use self-learning strategies and ampere-class lossless balance technology to ensure the consistency of the battery.
  • High-resolution thermal management functions can create the best operating temperature for the battery;
  • The intelligent interaction with PCS and monitoring platform can promote the automation of the storage industry;
  • The full range monitoring, control and maintenance technique will support the safe and sound operation of energy storage power plant.
 

EK-TY-21

sig energy

The system has a high-precision voltage detector, current detection, temperature detection, SOC estimation algorithm, loss balance, CAN BUS communication, RS485 communication, relay control, switch signal output, active signal input, etc.

1. SIZE

2. TECHNICAL PARAMETERS

NO.NamesSpecifications
1Voltage Detection Maximum strings support from the voltage detector: 24
Voltage detection range: 0 to 5 V (other voltages can be customized)
Voltage detection accuracy of ± 10 mV
2Temperature DetectionMaximum support from temperature detection: 4
Temperature sensing range of -40 °C to 125 °C
Temperature measurement accuracy ± 2 °C (-40 °C ~ 85 °C)
3Current DetectionCurrent ranges ± 500A (Current sensor optional)
Current measurement accuracy of ± 1%
4Relay Control2-way relay control, rated load current ≤ 1A peak current ≤ 2A
5Passive equilibriumAt the same time, can open 3-way balance under certain conditions, and different balances are independent of each other, the maximum current 250mA
6Balanced Failure ProtectionEffective protection of the battery safety
7485 Communications2-way 485 communication interface (1-way is only for data storage module)
8CAN Communications1-way CAN communication interface
9Active Signal Input2-way active signal input, rated load current of 0.5A, peak 1A
10Data DisplayLCD screen can be connected through the 485 BUS
Can connect the host computer via 485 or CAN
11SOC estimation error< 5%
12Failure alarmBuzzer sound alarm
13Data StorageCan add data storage module, Support 2 ~ 8G high-capacity SD data storage card
14System power consumption3W
15Operation voltage range12V system: DC9 ~ 18V (excluding LCD screen)
24V system: DC18 ~ 32V (excluding LCD screen)
16Operation tempreture range-30 ºC ~ 75 ºC
17Storage Temperature Range-40 ºC ~ 85 ºC
18Dimensions (mm)296*107*31

3. KEY FEATURES

  • The system adopts highly integrated automotive-level control chip which is compact size but with powerful functions;
  • The system realizes collection, testing, communication and control functions with only four interfaces, which greatly reduces the complexity of the inter-connection;
  • The system has high accuracy in voltage, current and temperature data collection;
  • The system adopts a double isolation design; each functional port is with protection, with high-security;
  • The system goes through EMC, high and low temperature, vibration, salt spray and other environmental testing, with strong reliability;
  • Efficient balance, one-way lossy balance maximum current can reach 250mA, and balance fail-safe function is designed to protect the battery;
  • Real-time display of system information via the LCD screen or PC;
  • Support 2 ~ 8G high-capacity data storage;
  • The system has strong electrical control interface isolation design, which can improve effective immunity.
 

EK-FT-21

sig energy

The system has a high-precision voltage detector, current detection, temperature detection, SOC estimation algorithm, lossy balance, CAN BUS communication, RS485 communication, relay control, switch signal output, active signal input, etc.

1. SIZE

2. TECHNICAL PARAMETERS

NO.NamesSpecifications
1Voltage Detection Maximum strings support from the voltage detector: 25 * n (n ≤ 25, total pressure ≤ 1000V)
Voltage detection range: 0 to 5 V (other voltages can be customized)
Voltage detection accuracy of ± 5 mV
2Temperature DetectionTemperature detection maximum support 25 * n (n ≤ 25)
Temperature sensing range of -40 °C to 125 °C
Temperature measurement accuracy ± 1 °C (-30 °C ~ 75 °C)
3Current DetectionCurrent ranges ± 1000A (Current sensor optional)
Current measurement accuracy of ± 1%
4BCU Module Relay Control3-way active output interface, 1-way passive output interface
Rated load current ≤ 1.2A, peak current ≤ 4A
5BMU Module Relay Control2-way relay control, rated load current ≤ 1.2A peak current ≤ 4A
6Passive EquilibriumAt the same time, can open 2-way balance under certain conditions, and different balances are independent of each other, the maximum current 250mA
7Balanced Failure ProtectionEffective protection of the battery safety
8485 Communications3-way 485 communication interface
9BCU Module CAN Communications3-way CAN communication interface
10BMU Module CAN Communications1-way CAN communication interface, can be used for the communication between a separate case and charger
11Switching Signal Output4-way switch signal output, the maximum load current of 500mA
12Active Signal Input2-way active signal input, 9 ~ 36V
13Data DisplayLCD screen can be connected through the 485 BUS
Can connect the host computer via 485 or CAN
14BMU Module Smoke Status Detection1-way switch signal input, detect smoke sensor signals (smoke sensor should withstand current > 20mA)
15BMU Module Charging connection confirmationJudge Whether The Charger connected the hardware
16SOC Estimation Error< 5%
17SOH Estimation Error< 10%
18Failure AlarmBuzzer sound alarm
BMU module has a green LED to indicate power status
BMU module has 3 red LED lights to display the fault code
19BCU Module Data StorageSupport 2 ~ 8G high-capacity SD data storage card
20BMU Module Data StorageWhen independent case is charging, can store the fault status data
21DTU InterfaceReserved DTU Interface using 485 protocol
22System Power ConsumptionThe BCU: 3W, the BMU: 1.5W
23Operation Voltage Range12V system: DC9 ~ 18V (excluding LCD screen)
24V system: DC18 ~ 31V (excluding LCD screen)
24Operation Tempreture Range-30 ºC ~ 75 ºC
25Storage Temperature Range-40 ºC ~ 85 ºC

3. KEY FEATURES

  • The system has high accuracy in voltage, current and temperature data collection;
  • The temperature detection and string numbers can have 1:1 high resolution;
  • The system designed smoke sensor signal detection interfaces to early warn potential risks of system and take preventive measures;
  • The system has charging connection confirmation interface, which can double confirm hardware and software and strengthen charging reliability;
  • The system adopts a double isolation design; each functional port is with protection, with high-security;
  • The system goes through EMC, high and low temperature, vibration, salt spray and other environmental testing, with strong reliability;
  • Efficient balance, one-way lossy balance maximum current can reach 250mA, and can open 2-way balance at the same time, a balance fail-safe function is designed to protect the battery Real-time display of system information via the LCD screen or PC;
  • Support 2 ~ 8G high-capacity data storage;
  • Reserved for the remote management interface, you can upload system date to server through a remote management module;
  • The system has multiple-way strong electrical control interface, isolate the control of weak and strong electric system, and improve effective immunity.
 

EK-FT-12

sig energy

The system has a high-precision voltage detector, current detection, temperature detection, SOC estimation algorithm, loss balance, CAN BUS communication, RS485 communication, relay control, switch signal output, active signal input, etc.

1. SIZE

2. TECHNICAL PARAMETERS

NO.NamesSpecifications
1Voltage Detection Maximum strings support from the voltage detector: 16 * n (n ≤ 25, total pressure ≤ 1000V)
Voltage detection range: 0 to 5 V (other voltages can be customized)
Voltage detection accuracy of ± 5 mV
2Temperature DetectionTemperature detection maximum support 3 * n (n ≤ 25)
Temperature sensing range of -40 °C to 125 °C
Temperature measurement accuracy ± 2 ° C (-40 °C ~ 85 °C)
3Current DetectionCurrent ranges ± 1000A (Current sensor optional)
Current measurement accuracy of ± 1%
4BCU Module Relay Control3-way active output interface, 1-way passive output interface
Rated load current ≤ 1.2A, peak current ≤ 4A
5BMU Module Relay Control2-way relay control, rated load current ≤ 1.2A peak current ≤ 4A
6Active EquilibriumCharge balance, charge low-voltage batteries; open all balances under certain conditions, and different balances are independent of each other, balanced current 2A±0.1A (room temperature)
7Equilibrium Current detectionReal-time Equilibrium current detection
8Balanced Failure protectionEffective protection of the battery safety
9485 Communications3-way 485 communication interface
10BCU Module CAN Communications3-way CAN communication interface
11BMU Module CAN Communications1-way CAN communication interface
12Switching Signal Output4-way switch signal output, the maximum load current of 500mA
13Active Signal Input2-way active signal input, 9 ~ 36V
14Data DisplayLCD screen can be connected through the 485 BUS
Can connect the host computer via 485 or CAN
15SOC Estimation Error< 5%
16Failure AlarmBuzzer sound alarm
17Data StorageSupport 2 ~ 8G high-capacity SD data storage card
18DTU InterfaceReserved DTU Interface using 485 protocol
19System Power ConsumptionBCU: 3W, BMU: 1W (when equilibrium, do not open)
20Operation voltage Range12V system: DC9 ~ 18V (excluding LCD screen)
24V system: DC18 ~ 32V (excluding LCD screen)
21Operation Temperature range-30 ºC ~ 75 ºC
22Storage Temperature Range -40 ºC ~ 85 ºC

3. KEY FEATURES

  • Efficient balance, one-way lossy balance maximum current can reach 1A, and can open 2-way balance at the same time, a balance fail-safe function is designed to protect the battery;
  • The system has high accuracy in voltage, current, temperature data collection;
  • The system adopts a double isolation design; each functional port is with protection, with high-security;
  • The system goes through EMC, high and low temperature, vibration, salt spray and other environmental testing, with strong reliability;
  • Real-time display of system information via the LCD screen or PC;
  • Support 2 ~ 8G high-capacity data storage;
  • Reserved for the remote management interface, you can upload system date to server through a remote management module;
  • The system has multiple-way strong electrical control interface, isolate the control of weak and strong electric system, and improve effective immunity.
 

YN.BMS EV-03

sig energy

Reference: YN.BMS EV-03

Data acquisition /calculation (monomer battery voltage/total voltage /temperature/ current/insulation /SOC estimation.
Communication function : CAN communication / Rs232 communication / R5485 communication
Status display function. failure classifying alarm

Description

External dimension : 220x160x42mm
Supporting solution : with the driving and driven structure. each slave control box is configured flexibly for
detecting the voltage of 60 circuits to the maximum limit
Applicable battery scope : Lead-acid battery, nickel-hydrogen battery, lithium battery and other power
batteries
Operating voltage range (WDC) : 12V (9-18V), 24V (16-28V)
Operating temperature range (℃) : -40°C - 85°C
Maximum relative operating humidity : 90%

1. Basic function

  • Data acquisition /calculation (monomer battery voltage/ total voltage / temperature/ current/insulation / SOC estimation)

  • Communication function : CAN communication / Rs232 communication

  • Status display function. failure classifying alarm function, control function (charging, discharging, heating, and fan), multi-10 control/ PWM expansion, balancing function, etc

2. Technical Index

  • Voltage measuring accuracy : 0.5%

  • Temperature measuring range (℃) : 40°C- 125°C

  • Temperature measuring accuracy (℃) : 0.5

  • Current measuring accuracy : 0.5%

  • SOC measuring accuracy : 5%

  • Monomer voltage cycle detection period : 20ms

  • Maximum current sampling period : 10ms

  • Application range of vehicle model : pure electric vehicle. hybrid electric vehicle

  • Application example : 2T pure electric sanitation vehicle, pure electric sedan, hybrid electric coach